Stability of Lyophilized Serum Control Material for Albumin Parameters During A Two-Month Storage Period Without Preservatives

Authors

  • Ally Kafesa Medical Laboratory Technology, Faculty of Health, Institut Kesehatan Rajawali, Indonesia Author
  • Septi Oktaviani Medical Laboratory Technology, Faculty of Health, Institut Kesehatan Rajawali, Indonesia Author
  • Sulis Sa'adah Medical Laboratory Technology, Faculty of Health, Institut Kesehatan Rajawali, Indonesia Author
  • Reza Maulana Medical Laboratory Technology, Faculty of Health, Institut Kesehatan Rajawali, Indonesia Author

DOI:

https://doi.org/10.68712/emy1de87

Keywords:

control material, lyophilized serum, albumin

Abstract

The capability of laboratory testing methods must produce a proportional response to the concentration of analytes in samples within the existing range. Quality assurance of data accuracy is obtained through the measurement of control materials at the pre-analytical stage. Control materials greatly influence the results of testing, and the use of unassayed control materials is preferred by many laboratories. The conversion of liquid control materials into powder (lyophilizate) by freeze drying has many advantages and avoids the effects of temperature and light. However, storage time still has the potential to change the structure of the material. Albumin is the main protein in the body that can undergo denaturation at its isoelectric point in liquid. The shelf life of liquid serum albumin is 2 months at a temperature of 15-25°C. Further testing is needed to determine the stability of albumin in lyophilized control material with a shelf life of 2 months at room temperature. This research method is quantitative descriptive with repeated measurements of powdered albumin after freeze drying using Six Sigma Westgard. Research results obtained under high-level conditions were an average albumin activity of 8.99 g/dL, TV 9.01 g/dL, SD: 0,77, CV%: 8,67, d%: 0,33, TE%: 17,01, and a six sigma value of 1.19 with MDC 5.2 g/dL (CLIA). The stability of albumin using the freeze-dry method was tested using the Horwitz CV (2-5 log C) with a value of 1.037 (≤3α, ISO 13528) and an absolute difference |Xr-Yr|= -0.1681 ≤ 0.0198. Conclusion: Freeze-dried albumin as a control material at the high level has good stability and can therefore be used as an alternative control material in the pre-analytical stage.

Downloads

Download data is not yet available.

Downloads

Published

2025-12-07

How to Cite

Stability of Lyophilized Serum Control Material for Albumin Parameters During A Two-Month Storage Period Without Preservatives. (2025). Chemistry Today, 1(1), 22-25. https://doi.org/10.68712/emy1de87

Most read articles by the same author(s)